Utilities SMIQ
1125.5555.03 E-92.426
2.29.12 Measurement of CARRIER/NOISE RATIO (DIAG-C/N MEAS)
The submenu DIAG - C/N MEAS can only be called with the option SMIQB17 (Noise generator and
distortion simulator). For C/N measurements in servicing the generator can be set to the service modes
as far are concerned. The carrier/noise ratio can then be easily determined this way. The submenu
DIAG - C/N MEAS offers an access to these modes.
Menu selection: UTILITIES - DIAG - C/N MEAS
SYSTEM
REF OSC
PHASE
PROTECT
CALIB
DIAG
TEST
MOD KEY
AUX I/O
BEEPER
INSTALL
CONFIG
TPOINT
C/N MEAS
PARAM
FREQ
100. 000 000 0
MHz
LEVEL
-30.0
dBm
TP 007
+3.570V
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
NOISE/DIST
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
C/N MEAS MODE... CARRIER NOISE
CARRIER
NOISE
Fig. 2-270 Menu UTILITIES - DIAG - C/N MEAS
CARRIER NOISE
Noise and carrier signal
IEC/IEEE-bus command :DIAG:CNM:MODE CN
CARRIER
Only carrier signal
IEC/IEEE-bus command :DIAG:CNM:MODE CARR
NOISE
Only noise signal
IEC/IEEE-bus command :DIAG:CNM:MODE NOIS