EasyManua.ls Logo

Rohde & Schwarz SML01 - Page 102

Rohde & Schwarz SML01
299 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stereo Modulation (Option R&S SML-B5) R&S®SML / R&S®SMV03
1090.3123.12 E-6 4.24
BK
Des
cription: Sets the ARI area identification.
Command: BK=x
Query: BK?
Response: x
Value range: A-F
Example: Command:
STEReo:DIRect “BK=E“
The ARI area identification is set to "E".
Query:
STEReo:DIRect? “BK“
Response:
"E"
CT
Description: Sets and activates transmission of the real-time clock.
Command: CT= XX:YY:ZZ,TT.MM.JJ
XX = hour, YY = minute, ZZ = second
TT = day, MM = month, JJ = year
Query: CT?
Response: XX:YY:ZZ,TT.MM.JJ
Value range: 00:00:00,01.01.00 bis 23:59:59,31.12.85
(ASCII coded decimal numbers)
Example: Command:
STEReo:DIRect "CT=20:30:59,01.08.03"
The real-time clock is set to 20:30:59 and 1 August 2003.
Query:
STEReo:DIRect? “CT“
Response:
"20:31:06,01.08.03"
Note: The CT data is transmitted in group 4A. Setting the real-time clock (CT command)
automatically adds group 4A to the group sequence. Group 4A must not be manually
added to, or removed from, the group sequence. To remove group 4A from the group
sequence, the "CT=off" command must be used.
CT=off
Description: Deactivates transmission of the real-time clock signal in the RDS signal.
Command: CT=off
Example: Command:
STEReo:DIRect "CT=off"
The real-time clock signal is no longer transmitted in the RDS signal.
Note: This command is used to remove group 4A from the group sequence. Group 4A must not
be manually removed from the group sequence.