R&S®SML / R&S®SMV03 Stereo Modulation (Option R&S SML-B5)
1090.3123.12 4.25 E-6
DI
Description: Sets or reads the decoder information.
With this command, the current decoder operating mode (mono, stereo, etc) can
be detected and, if necessary, changed.
Command: DI=x
Query: DI?
Response: x
Value range: 0-F (ASCII coded hexadecimal numbers)
Example: Command:
STEReo:DIRect “DI=4“
The decoder information is set to "4".
Query:
STEReo:DIRect? “DI“
Response:
"4"
DS
Description: Selects/activates a storage area in the Stereo/RDS Coder.
Upon activation, the settings stored in the selected area can be loaded.
Command: DS=x
Query: DS?
Response: x
Value range: 1|2|3|4|5|6|7|8|9
Example: Command:
STEReo:DIRect “DS=2“
Storage area 2 is activated.
Query:
STEReo:DIRect? “DS“
Response:
"2"