Instrument Function
R&S
®
SMU200A
418Operating Manual 1007.9845.32 ─ 15
Depending on the configuration of the multi carrier waveform, calculation may take some
time. A panel with a progress bar and an "Abort" button appears during the calculation
process.
SCPI command:
[:SOURce<hw>]:BB:ARB:MCARrier:CREate on page 603
Create and Load
Creates a new multi carrier waveform defined by the multi carrier table and General Set-
ting entries and loads it subsequently in the "ARB" main menu.
This multi carrier waveform is saved with the file name specified in "Output File". If no file
name is specified, the File Manager opens so that the file name can be entered. As with
normal waveforms, the file extension is *.wv.
Depending on the configuration of the multi carrier waveform, calculation may take some
time. A panel with a progress bar and an "Abort" button appears during the calculation
process.
SCPI command:
[:SOURce<hw>]:BB:ARB:MCARrier:CLOad on page 603
Muti Carrier Table
The "Multi Carrier Table" manu is oped by means of the "Carrier Table" button in the
middle part of the Multi Carrier Waveforms menu. The carrier settings can be checked in
the graphical "Carrier Graph" submenu.
The "Carrier Table Assistant" section can be used to set a selectable carrier range. This
section serves as a optional mean to quickly set up a multi carrier scenario within a
specified carrier range.
Baseband Signal - Baseband Block