Remote Control Commands
R&S
®
SMU200A
558Operating Manual 1007.9845.32 ─ 15
SENSe<ch>[:POWer]:DISPlay:PERManent:PRIority..........................................................559
SENSe<ch>[:POWer]:FILTer:LENGth:AUTO....................................................................560
SENSe<ch>[:POWer]:FILTer:LENGth[:USER]...................................................................560
SENSe<ch>[:POWer]:FILTer:NSRatio..............................................................................561
SENSe<ch>[:POWer]:FILTer:NSRatio:MTIMe...................................................................561
SENSe<ch>[:POWer]:FILTer:SONCe...............................................................................561
SENSe<ch>[:POWer]:FILTer:TYPE.................................................................................562
SENSe<ch>[:POWer]:FREQuency...................................................................................562
SENSe<ch>[:POWer]:OFFSet.........................................................................................563
SENSe<ch>[:POWer]:OFFSet:STATe..............................................................................563
SENSe<ch>[:POWer]:SNUMber......................................................................................563
SENSe<ch>[:POWer]:SOURce.......................................................................................564
SENSe<ch>[:POWer]:STATus[:DEVice]...........................................................................564
SENSe<ch>[:POWer]:SVERsion.....................................................................................564
SENSe<ch>[:POWer]:TYPE............................................................................................565
SENSe<ch>[:POWer]:ZERO...........................................................................................565
SENSe<ch>:UNIT[:POWer].............................................................................................565
INITiate<ch>[:POWer]:CONTinuous <Continuous>
The command switches the local state of the continuous power measurement by the R&S
NRP-Zxx power sensors on and off. Switching the local state off enhances the measure-
ment performance during remote control
The remote measurement is triggered by the READ query which also provides the mea-
surement results. The local state is not influenced by this command, measurements
results can be retrieved with local state on or off.
Parameters:
0|1|OFF|ON
OFF
<Continuous>
*RST:
INIT:CONT ON
switches local state of continuous power measurement on.
Example:
READ<ch>[:POWer]?
The command triggers the measurement with power sensors and provides the power
measurement result of the selected power sensor. The value is provided with the unit set
with command SENSe:UNIT[:POWer].
For certain power sensors, e.g. R&S NRP-Z81, two values are returned, first the value
for the average level and - separated by a comma - the peak level
Note: The local state is not influenced by this command, measurements results can be
retrieved with local state on or off. For long measurement times it is recommended to use
a SRQ (MAV bit) for command synchronization.
Return values:
string<Power>
SENSe, READ and INITiate Subsystems