Remote Control Commands
R&S
®
SMU200A
593Operating Manual 1007.9845.32 ─ 15
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:ONTime <Ontime>
The command sets the number of samples in a period (ON time + OFF time) during which
the marker signal in setting :ARB:TRIGger:OUTPut:MODE RATio on the marker out-
puts is ON.
Parameters:
float
1
1
<Ontime>
Increment:
*RST:
BB:ARB:TRIG:OUTP2:ONT 20
sets an ON time of 20 samples for marker 2
In case of two-path instruments, on path A.
Example:
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:PATTern <Pattern>
The command defines the bit pattern used to generate the marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PATTern 0 is marker off, 1 is marker on.
Parameters:
<32 bits pattern>
0
<Pattern>
*RST:
BB:ARB:TRIG:OUTP2:PATT #H39FE0000,32
sets a bit pattern.
BB:ARB:TRIG:OUTP2:MODE PATT
activates the marker signal according to a bit pattern on output
MARKER 2.
Example:
[:SOURce<hw>]:BB:ARB:TRIGger:OUTPut<ch>:PULSe:DIVider <Divider>
The command sets the divider for the pulsed marker signal in the setting
SOURce:BB:ARB:TRIGger:OUTPut:MODE PULSe. The pulse frequency is derived by
dividing the symbol rate by the divider.
Parameters:
float
2 to 2^10
1
2
<Divider>
Range:
Increment:
*RST:
BB:ARB:TRIG:OUTP2:PULS:DIV 2
sets the divider for the marker signal on output MARKER 2 to the
value 2.
BB:ARB:TRIG:OUTP2:FREQ?
queries the resulting pulse frequency of the marker signal
Response: 66 000
the resulting pulse frequency is 66 kHz.