Remote Control Commands
R&S
®
SMU200A
621Operating Manual 1007.9845.32 ─ 15
7.15.3.3 SOURce:BB:DM Subsystem
The commands in the SOURce:BB:DM subsystem are described in two sections, sepa-
rated into configuring digital modulation and lists for digital modulation.
DM General Remote-Control Commands
The following section contains the commands for generating the digital modulation signal.
Common Settings..................................................................................................621
Clock Settings.......................................................................................................624
Trigger Settings.....................................................................................................626
Marker Settings.....................................................................................................633
Filter Settings........................................................................................................636
Modulation Settings...............................................................................................639
Power Ramp.........................................................................................................642
Common Settings
[:SOURce<hw>]:BB:DM:PATTern....................................................................................621
[:SOURce<hw>]:BB:DM:PRBS[:LENGth]..........................................................................621
[:SOURce<hw>]:BB:DM:PRESet.....................................................................................622
[:SOURce<hw>]:BB:DM:SOURce....................................................................................622
[:SOURce<hw>]:BB:DM:SRATe......................................................................................623
[:SOURce<hw>]:BB:DM:STANdard..................................................................................623
[:SOURce<hw>]:BB:DM:STATe.......................................................................................624
[:SOURce<hw>]:BB:DM:SWITching:SOURce...................................................................624
[:SOURce<hw>]:BB:DM:SWITching:STATe......................................................................624
[:SOURce<hw>]:BB:DM:PATTern <Pattern>
The command selects the data pattern for the internal data when PATTern is selected
as the data source. The maximum length is 64 bits.
Parameters:
integer
#B0,1 to #B111...1,64
#B0,1
<Pattern>
Range:
*RST:
BB:DM:SOUR PATT
selects Pattern as the data source for digital modulation.
BB:DM:PATT #B01110111010101010,17
generates the user-defined sequence of 0/1 data.
Example:
[:SOURce<hw>]:BB:DM:PRBS[:LENGth] <Length>
The command defines the length of the pseudo-random sequence in accordance with
the following equation:
Length = (2^LENGth) - 1