Remote Control Commands
R&S
®
SMU200A
629Operating Manual 1007.9845.32 ─ 15
Parameters:
float
0 to 2^26-1 Symbols
1 symbol
0 symbols
symbol
<Inhibit>
Range:
Increment:
*RST:
Default unit:
BB:DM:TRIG:SOUR OBAS
sets for path A the internal trigger executed by the trigger signal
from the second path (path B).
BB:DM:TRIG:INH 200
sets a restart inhibit for 200 symbols following a trigger event.
Example:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut:DELay:FIXed <Fixed>
The command restricts the marker delay setting range to the dynamic range. In this range
the delay can be set without restarting the marker and signal. If a delay is entered in
setting ON but is outside this range, the maximum possible delay is set and an error
message is generated.
The numeric suffix in OUTPut has no significance for this command, since the setting
always affects every marker.
Parameters:
0|1|OFF|ON
OFF
<Fixed>
*RST:
BB:DM:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
Example:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay <Delay>
The command defines the delay between the signal on the marker outputs and the start
of the signal, expressed in terms of symbols. Command
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut:DELay:FIXed can be used to restrict
the range of values to the dynamic range, i.e. the range within which a delay of the marker
signals can be set without restarting the marker and signal.
Parameters:
float
0 to 100 000 Symbols
1 symbol
0 symbol
<Delay>
Range:
Increment:
*RST:
BB:DM:TRIG:OUTP2:DEL 16
sets a delay of 16 symbols for the signal on connector MARKER
2.
Example:
SOURce Subsystem