Remote Control Commands
R&S
®
SMU200A
662Operating Manual 1007.9845.32 ─ 15
SOURce:BB:IMP:OPT:UCOR:ACC?
queries the accuracy of the frequency response correction data.
Response: LOW | NORMal | HIGH
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:BWIDth?
Note: Bandwidth of the user correction data is only indicated if the instrument is equipped
with an R&S SMx-K63 and external devices are enabled.
This command queries the bandwidth of the frequency response correction data.
Return values:
BWFRange|BW5M|BW10M|BW15M|BW20M|BW30M|BW40M|
BW60M|BW80M
<Bwidth>
SOURce:BB:IMP:OPT:UCOR:BWID?
queries the bandwidth of the frequency response correction data.
Response: BWFRange | BW5M | BW10M | BW15M |
BW20M | BW30M | BW40M | BW60M | BW80M
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:CATalog?
The command queries the names of the frequencies response correction files with the
predefined file extension *.frc. The standard directory for frequency response correction
files is D:\SMxRFandBBCorrectionTooolkit\SMxK63 on the hard disk of the instru-
ment. A complete list of all files is returned (the various entries are separated by commas).
Return values:
string<Catalog>
MMEM:CDIR 'd:
/SMxRFandBBCorrectionToolkit/SMxK63'
switches to the default directory for *.frc files.
SOUR:BB:IMP:OPT:UCOR:CAT?
queries the names of the frequency response correction files.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:EDEVices?
Set to On this command enables that the parameters bandwidth, frequency offset and
level offset are displayed.