Remote Control Commands
R&S
®
SMU200A
664Operating Manual 1007.9845.32 ─ 15
Return values:
OK|MISSing|INCompatible|CORRupt
OK
File type and data of the correction file are ok. The file can be used
for frequency response correction.
MISS
File not found.
INC
The file is not compatible with the instrument or the path and could
not be loaded.
CORR
The frequency response correction data is corrupt. An error
occured and the file could not be loaded.
<Status>
SOUR:BB:IMP:OPT:UCOR:FILE:STAT?
queries the status of file loading.
Response: OK
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FREQuency:MAX?
Note: Frequency values of the user correction data are only indicated if the instrument
is equipped with an R&S SMx-K63.
The command displays the maximum frequency value of the frequency response cor-
rection data.
Return values:
float<Max>
SOURce:BB:IMP:OPT:UCOR:FREQ:MAX?
queries the maximum frequency value of the correction data.
Response: xxxx.x MHz
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:IMPairment:OPTimization:UCORrection:FREQuency:MIN?
Note: Frequency values of the user correction data are only indicated if the instrument
is equipped with an R&S SMx-K63.
The command displays the minimum frequency value of the frequency response correc-
tion data.
Return values:
float<Min>
SOURce:BB:IMP:OPT:UCOR:FREQ:MIN?
queries the minimum frequency value of the correction data
Response: yyyy.y MHz
Example:
SOURce Subsystem