Remote Control Commands
R&S
®
SMU200A
668Operating Manual 1007.9845.32 ─ 15
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:POWer:STEP.................................................675
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:POWer[:STARt]...............................................675
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STARt............................................................676
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STATe...........................................................676
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STOP.............................................................676
[:SOURce<hw>]:BB:MCCW:STATe <State>
The command turns on the Multi Carrier CW signal. Any other digital standards or digital
modulation that may be in the ON state will be automatically turned OFF.
In case of two-path instruments, this affects the same path.
Parameters:
0|1|OFF|ON
OFF
<State>
*RST:
BB:MCCW:STAT ON
switches on generation of the Multi Carrier CW signal.
Example:
[:SOURce<hw>]:BB:MCCW:PRESet
The command sets all multi carrier signal parameters to their default values.
BB:MCCW:PRESet
resets the Multi Carrier settings to default values.
Example:
EventUsage:
[:SOURce<hw>]:BB:MCCW:CARRier:COUNt <Count>
The command sets the number of carriers in the Multi Carrier CW signal. The total band-
width is calculated as (Number of carriers - 1) * Carrier spacing and must not exceed the
system bandwidth of the instrument (see data sheet).
The carrier spacing (:BB:MCCW:CARRier:SPACing) is reduced if the total bandwidth
is not respected when entering the number of carriers.
The number of carriers entered therefore defines the maximum carrier spacing
(:BB:MCCW:CARRier:SPACing).
Parameters:
integer
1 to 8192
1
64
<Count>
Range:
Increment:
*RST:
BB:MCCW:CARR:COUN 10
sets 10 CW carriers for the multi carrier signal.
Example: