Remote Control Commands
R&S
®
SMU200A
682Operating Manual 1007.9845.32 ─ 15
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut:DELay:FIXed <Fixed>
The command restricts the marker delay setting range to the dynamic range. In this range
the delay can be set without restarting the marker and signal. If a delay is entered in
setting ON but is outside this range, the maximum possible delay is set and an error
message is generated.
The numeric suffix in OUTPut has no significance for this command, since the setting
always affects every marker.
Parameters:
0|1|OFF|ON
OFF
<Fixed>
*RST:
BB:MCCW:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
Example:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay <Delay>
The command defines the delay between the signal on the marker outputs and the start
of the signal, expressed in terms of symbols. Command
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut:DELay:FIXed can be used to restrict
the range of values to the dynamic range, i.e. the range within which a delay of the marker
signals can be set without restarting the marker and signal.
Parameters:
0 to 100 000 Symbols
0 Symbols
<Delay>
Range:
*RST:
BB:MCCW:TRIG:OUTP2:DEL 16
sets a delay of 16 symbols for the signal on connector MARKER
2.
Example:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay:MAXimum?
The command queries the maximum marker delay for set-
ting :BB:DM:TRIG:OUTP:DEL:FIX ON.
Return values:
float<Maximum>
BB:MCCW:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:MCCW:TRIG:OUTP:DEL:MAX
queries the maximum of the dynamic range.
Response: 2000
the maximum for the marker delay setting is 2000 symbols.
Example: