Remote Control Commands
R&S
®
SMU200A
683Operating Manual 1007.9845.32 ─ 15
Query onlyUsage:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay:MINimum?
The command queries the minimum marker delay for set-
ting :BB:MCCW:TRIGger:OUTPut:DELay:FIXed ON.
Return values:
float<Minimum>
BB:MCCW:TRIG:OUTP:DEL:FIX ON
restricts the marker signal delay setting range to the dynamic
range.
BB:MCCW:TRIG:OUTP:DEL:MIN
queries the minimum of the dynamic range.
Response: 0
the minimum for the marker delay setting is 0 symbols.
Example:
Query onlyUsage:
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:MODE <Mode>
The command defines the signal for the selected marker output.
Parameters:
RESTart|PULSe|PATTern|RATio
RESTart
A brief marker signal is generated at the start of the waveform.
PULSe
A pulsed marker signal is generated. The pulse frequency (=
sample rate/divider) is defined with the
SOUR:BB:MCCW:TRIG:OUTP:PULSe:DIVider command and
can be queried with the
SOUR:BB:MCCW:TRIG:OUTP:PULSe:FREQuency? command.
PATTern
A marker signal is generated with the aid of a user-definable bit
pattern. The bit pattern is entered with the aid of command
SOURce:BB:MCCW:TRIGger:OUTPut:PATTern. The bit
pattern is a maximum of 32 bits long.
RATio
A regular marker signal corresponding to the Time Off / Time On
specifications in the commands
SOURce:BB:MCCW:TRIGger:OUTPut:OFFT and
SOURce:BB:MCCW:TRIGger:OUTPut:ONT is generated.
RESTart
<Mode>
*RST:
BB:MCCW:TRIG:OUTP2:MODE PULS
selects the pulsed marker signal on output MARKER 2.
Example:
SOURce Subsystem