Remote Control Commands
R&S
®
SMU200A
728Operating Manual 1007.9845.32 ─ 15
7.15.10 SOURce:IQ:OUTput Subsystem
7.15.10.1 Analog I/Q Outputs
This subsystem contains the commands for configuring the differential output.
For information about the required options, see chapter 5.7.3.2, "Analog I/Q Output",
on page 309.
[:SOURce]:BB:IQOutput:SOURce....................................................................................728
[:SOURce<hw>]:IQ:OUTPut:BIAS:COUPling[:STATe]........................................................728
[:SOURce<hw>]:IQ:OUTPut:BIAS:I..................................................................................729
[:SOURce<hw>]:IQ:OUTPut:BIAS:Q................................................................................729
[:SOURce<hw>]:IQ:OUTPut:BIAS:OPTimization[:RF]:STATe.............................................730
[:SOURce<hw>]:IQ:OUTPut:LEVel..................................................................................730
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:POWer:PEP..........................................................730
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:POWer:PEP:RESult...............................................731
[:SOURce<hw>]:IQ:OUTPut:MODE.................................................................................731
[:SOURce<hw>]:IQ:OUTPut:OFFSet:I..............................................................................732
[:SOURce<hw>]:IQ:OUTPut:OFFSet:Q............................................................................732
[:SOURce<hw>]:IQ:OUTPut:TYPE...................................................................................733
[:SOURce]:BB:IQOutput:SOURce <Source>
This command selects the output signal at the I/Q OUT connectors for a two-path instru-
ment.
Parameters:
A | B
A
<Source>
*RST:
BB:IQO:SOUR A
the I/Q components of path A baseband signal are output at the I/
Q OUT connectors.
Example:
[:SOURce<hw>]:IQ:OUTPut:BIAS:COUPling[:STATe] <State>
This command activates/deactivates coupling of bias setting of the I-signal and Q-signal
component.
If coupling is activated, settings made for the I-signal component
(SOUR:IQ:OUT:BIAS:I) automatically applies to the Q-signal
(SOUR:IQ:OUT:BIAS:Q)
For two-path instruments, the outputs are assigned with command
SOURce:BB:IQOut:SOURce.
Parameters:
0|1|OFF|ON
ON
<State>
*RST:
SOURce Subsystem