EasyManua.ls Logo

Rohde & Schwarz SMU200A - Page 799

Rohde & Schwarz SMU200A
888 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMU200A
779Operating Manual 1007.9845.32 ─ 15
SOUR:SWE:SHAP TRI
selects the sweep cycle with alternating ascending and descend-
ing sweep directions.
Example:
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing <Spacing>
The command selects linear or logarithmic sweep spacing.
The keyword [:FREQuency] can be omitted (see example). The command is then SCPI-
compliant.
Parameters:
LINear|LOGarithmic
LIN
<Spacing>
*RST:
SWE:SPAC LIN
selects linear sweep spacing for a frequency sweep at the RF out-
put.
Example:
[:SOURce<hw>]:SWEep[:FREQuency]:STEP[:LINear] <Linear>
The command sets the step width for linear sweeps.
This command is linked to the command :SWEep[:FREQuency]:POINts as follows:
POINts = (SPAN / STEP:LIN) + 1
If STEP:LIN changes, the value of POINTs is adjusted. The STARt and STOP value is
retained.
The keywords [:FREQuency] and [:LINear] can be omitted (see example). The com-
mand is then SCPI-compliant.
Correlation: The value of :SWE:POINts is adjusted automatically.
Parameters:
float
0 to (STOP - STARt)
0.1Hz
1MHz
Hz
<Linear>
Range:
Increment:
*RST:
Default unit:
SOURce Subsystem

Table of Contents