Remote Control Commands
R&S
®
SMU200A
817Operating Manual 1007.9845.32 ─ 15
R&S SMIQ Command Short description R&S
SMU
Remarks
[SOURce[1]:]PULM:POLarity
Polarity pulse modulation X
[SOURce[1]:]PULM:STATe
Pulse modulation on/off X
[SOURce[1]:]ROSCillator:
...
Reference frequency X
[SOURce[1]:]ROSCillator:
EXTernal:FREQuency
Frequency of the external ref-
erence
X
[SOURce[1]:]ROSCillator[:
INTernal]:ADJust:VALue
Adjustment value X
[SOURce[1]:]ROSCillator[:
INTernal]:ADJust[:STATe]
Fine adjustment of the fre-
quency on/off
X
[SOURce[1]:]ROSCillator:
SOURce
Reference frequency source X
[SOURce[1]:]SWEep...
RF sweeps
SOURce<[1]|2>:
SWEep:....
[SOURce[1]:]SWEep:BTIMe
Blank time sweep -
[SOURce[1]:]SWEep[:
FREQuency]:DWELl
Dwell time X
[SOURce[1]:]SWEep[:
FREQuency]:MODE
Sweep mode X
[SOURce[1]:]SWEep[:
FREQuency]:POINts
Number of steps in an RF
sweep
X
[SOURce[1]:]SWEep[:
FREQuency]:SPACing
Sweep spacing X
[SOURce[1]:]SWEep[:
FREQuency]:STEP:
LOGarithmic
Step width factor for logarith-
mic sweeps
X
[SOURce[1]:]SWEep[:
FREQuency]:STEP[:LINear]
Step width for linear sweeps X
[SOURce[1]:]SWEep:POWer:
DWELl
Time for each level step X
[SOURce[1]:]SWEep:POWer:
MODE
Sweep mode X
[SOURce[1]:]SWEep:POWer:
POINts
Number of steps in a level
sweep
X
[SOURce[1]:]SWEep:POWer:
STEP[:LOGarithmic]
Step width factor for logarith-
mic sweeps
X
:SOURce2:...
LF generator sweep
SOURce<[1]|2>:
LFOutput:SWEep
:SOURce2:SWEep:BTIMe
Blank Time -
:SOURce2:SWEep[:
FREQuency]:DWELl
Dwell time for each frequency
step
X
Alphabetical List of R&S SMIQ Commands