Remote Control Commands
R&S
®
SMU200A
818Operating Manual 1007.9845.32 ─ 15
R&S SMIQ Command Short description R&S
SMU
Remarks
:SOURce2:SWEep[:
FREQuency]:MODE
Sweep mode LF sweep X
:SOURce2:SWEep[:
FREQuency]:POINts
Number of steps in an LF
sweep
X
:SOURce2:SWEep[:
FREQuency]:SPACing
Lin or log LF sweep X
:SOURce2:SWEep[:
FREQuency]:STEP:
LOGarithmic
Step width for the log sweep X
:SOURce2:SWEep[:
FREQuency]:STEP[:LINear]
Step width for the linear sweep X
[:SOURce]:W3GPp:....
3GPP FDD
[SOURce<[1]|2>:
]BB:W3GPp:...
[:SOURce]:W3GPp:BSTation:
ENHAnced:..
Enhanced base station - extended functions
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
CCODe
Channelization code X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
DATA
Data source X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
DATA:PATTern
Data pattern X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
MCODe
Multicode on/off -
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
PLENgth
Length of the pilot fields -
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
POWer
Channel power X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
SRATe
Symbol rate X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
STATe
Channel on/off X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:
TOFFset
Timing Offset X
[:SOURce]:W3GPp:
BSTation<n>:CHANnel<n>:TPC
TPC data source -