5G New Radio Configuration and Settings
R&S
®
SMW-K144
119User Manual 1178.8013.02 ─ 06
Second Hop PRB........................................................................................................ 119
Initial Cyclic Shift......................................................................................................... 119
Time Domain OCC Index............................................................................................ 119
OCC Length................................................................................................................ 120
OCC Index.................................................................................................................. 120
Group Hopping
Sets the higher-layer parameter pucch-GroupHopping, as defined in TS 38.211.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:GRPHopping on page 250
Hopping ID
Sets the parameter hopping ID (n
ID
) used to select the frequency hopping sequence
number and to initialize the pseudo-random sequence generator. In the practice, the
value is transmitted by the higher-layer parameter hoppingId [TS 38.211].
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:HOPid on page 250
Intra Slot Frequency Hopping
Enables intra-slot frequency hopping.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:ISFHopping on page 250
Second Hop PRB
Sets the physical resource block (PRB) of the second hop.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:SHOPping on page 251
Initial Cyclic Shift
For PUCCH formats F0 and F1, sets the initial cyclic shift.
As defined in TS 38.211, the value is required to calculate the cyclic shift for the hop-
ping sequence and thus define the frequency positions of the different hops.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:FS:CYCShift on page 251
Time Domain OCC Index
For PUCCH format F1, sets the orthogonal sequence index I (I = 0 to 6). As defined in
TS 38.211, the value is required to select the orthogonal sequence, used for the block-
wise spreading.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:FS:TDOCc on page 251
PUCCH Settings