5G New Radio Configuration and Settings
R&S
®
SMW-K144
121User Manual 1178.8013.02 ─ 06
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:PL:SRCount on page 252
Number of ACK Bits
Sets the number of ACK bits and defines the length of the "ACK Pattern" field.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:PL:ACK:BITS on page 252
ACK Pattern
Sets the ACK bits in pattern form, where the pattern length is set with the parameter
"Number of ACK Bits".
A "1" indicates an ACK, a "0" - a NACK.
The pattern is read out once.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:PL:ACK:PATTern on page 253
Number of UCI Bits
Sets the number of UCI bits and defines the length of the "UCI Pattern" field.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:PL:UCI:BITS on page 252
UCI Pattern
Sets the UCI bit sequence according to TS 38.212. The sequence is set in pattern
form, where the pattern length is set with the parameter "Number of UCI Bits".
A "1" indicates an ACK, a "0" - a NACK.
The pattern is read out once.
Remote command:
[:SOURce<hw>]:BB:NR5G:SCHed:CELL<ch0>:SUBF<st0>:USER<dir0>:
BWPart<gr0>:ALLoc<user0>:PUCCh:PL:UCI:PATTern on page 253
5.8 PRACH Settings
Access:
1. Select "5G New Radio > General > Link Direction > Uplink".
2. Select "5G New Radio > Scheduling".
3. Select "User x BWP x > Content > PRACH".
PRACH Settings

Table of Contents