Remote-Control Commands
R&S
®
SMW-K144
165User Manual 1178.8013.02 ─ 06
Example: See Example "Storing current configuration" on page 147.
Manual operation: See "Save/Recall" on page 23
[:SOURce<hw>]:BB:NR5G:SETTing:LOAD <Filename>
Loads the selected file from the default or the specified directory. Loaded are files with
extension *.nr5g.
Parameters:
<Filename> "<filename>"
Filename or complete file path; file extension can be omitted
Example: See Example "Storing current configuration" on page 147.
Manual operation: See "Save/Recall" on page 23
[:SOURce<hw>]:BB:NR5G:SETTing:DEL
<Filename>
Deletes the selected file from the default or the specified directory. Deleated are files
with extension *.nr5g.
Parameters:
<Filename> "<filename>"
Filename or complete file path; file extension can be omitted
Example: See Example "Storing current configuration" on page 147.
Manual operation: See "Save/Recall" on page 23
[:SOURce<hw>]:BB:NR5G:SETTing:TMODel:UL <TmodUp>
[:SOURce<hw>]:BB:NR5G:SETTing:TMODel:DL <TmodDn>
Loads a files with predefined settings.
Parameters:
<TmodDn> "<filename>"
Filename as queried with the command [:SOURce<hw>]:BB:
NR5G:SETTing:TMODel:DL:CATalog?.
Example: See Example "Loading predefined test signals" on page 148.
Manual operation: See "Test Models" on page 25
[:SOURce<hw>]:BB:NR5G:SETTing:TMODel:UL:CATalog?
[:SOURce<hw>]:BB:NR5G:SETTing:TMODel:DL:CATalog?
Queries the filenames of predefined files with test signals in the default directory.
Return values:
<FileNames> <filename1>,<filename2>,...
Returns a string of filenames separated by commas.