Remote-Control Commands
R&S
®
SMW-K144
170User Manual 1178.8013.02 ─ 06
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S15K:OFFSet.................................. 171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S60K:OFFSet.................................. 171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S30K:OFFSet.................................. 171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S120K:KOMU?................................ 171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S15K:KOMU?..................................171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S60K:KOMU?..................................171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S30K:KOMU?..................................171
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:POINta <CarrierPointA>
Sets the frequency offset between the reference Point A and the center carrier fre-
quency.
Parameters:
<CarrierPointA> float
Range: -50e6 to 0
Increment: 0.015
*RST: 49140000
Example: See Example "Configuring the TxBWs" on page 149.
Manual operation: See "Point A to Carrier Center" on page 33
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:CONFlict?
Queries whether there is a conflict.
Return values:
<Conflict> 0 | 1 | OFF | ON
*RST: n.a. (no preset. default: 0)
Example: See Example "Configuring the TxBWs" on page 149.
Usage: Query only
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:RESolve
Recalculates the frequency-dependent settings and thus redefines the frequency posi-
tion of the TxBW.
Example:
See Example "Configuring the TxBWs" on page 149.
Usage: Event
Manual operation: See "Resolve Conflicts" on page 34
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S120K:USE <ScsUse>
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S15K:USE <ScsUse>
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S60K:USE <ScsUse>
[:SOURce<hw>]:BB:NR5G:NODE:CELL<ch0>:TXBW:S30K:USE <ScsUse>
Enables a SCS in the particular cell.