[:SOURce<hw>]:BB:NR5G:OUTPut:FBWP:STATe <FilterBWP>
Defines if and how the filter is applied, on the whole channel bandwidth or on the indi-
vidual BWPs separately.
Parameters:
<FilterBWP> 0 | 1 | 2
0 = per channel bandwidth
1 = per BWP
2 = off (disables filtering)
*RST: 0
Example: See Example "Output settings" on page 162.
Manual operation: See "Filter Mode" on page 134
[:SOURce<hw>]:BB:NR5G:OUTPut:SAMRmode
<SampRateMode>
Sets the sample rate mode.
Parameters:
<SampRateMode> MIN | FFT
*RST: FFT
Manual operation: See "Sample Rate Mode" on page 135
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:SRATe?
Queries the resulting sample rate.
Suffix:
<ch0>
.
0 to 7
Return values:
<SampleRate> integer
Among others, value range depends on the selected deploy-
ment scenario and channel bandwidth.
Range: 4E6 to 5E8
*RST: 4E6
Example: See Example "Output settings" on page 162.
Usage: Query only
Manual operation: See "Sample Rate" on page 135
See "Playback Rate" on page 136
[:SOURce<hw>]:BB:NR5G:OUTPut:BBConf:ROW<ch0>:CONFlict <Conflict>
Queries if there are conflicting settings.
Output Commands