Remote Control Commands
R&S
®
SMW200A
1001User Manual 1175.6632.02 ─ 16
Parameters:
<Delay> float
Range: 0 to 16777215
Increment: 0.001
*RST: 0
Example: See "Programming Examples" on page 983
Manual operation: See "Marker x Delay" on page 260
Clock Settings
[:SOURce<hw>]:BB:MCCW:CLOCk:SOURce................................................................. 1001
[:SOURce<hw>]:BB:MCCW:CLOCk:MODE.................................................................... 1001
[:SOURce<hw>]:BB:MCCW:CLOCk:SOURce <Source>
Selects the clock source:
INTernal: Internal clock reference
ELCLock: External local clock
EXTernal = ELCLock: Setting only
Provided for backward compatibility with other Rohde & Schwarz signal generators
Parameters:
<Source> INTernal | ELCLock | EXTernal
*RST: INTernal
Example: see "Programming Examples" on page 983
Options: ELCLock requires R&S SMW-B10
Manual operation: See "Clock Source" on page 260
[:SOURce<hw>]:BB:MCCW:CLOCk:MODE <Mode>
Sets the type of externally supplied clock.
Parameters:
<Mode> SAMPle
*RST: SAMPle
Example: See "Programming Examples" on page 983
Options: R&S SMW-B10
Manual operation: See "Clock Mode" on page 261