Remote Control Commands
R&S
®
SMW200A
1005User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:AWGN:BWIDth:NOISe?....................................................................... 1006
[:SOURce<hw>]:AWGN:DISP:MODE.............................................................................1007
[:SOURce<hw>]:AWGN:POWer:MODE..........................................................................1007
[:SOURce<hw>]:AWGN:POWer:RMODe........................................................................1007
[:SOURce<hw>]:AWGN:BRATe.....................................................................................1008
[:SOURce<hw>]:AWGN:CNRatio...................................................................................1008
[:SOURce<hw>]:AWGN:ENRatio...................................................................................1008
[:SOURce<hw>]:AWGN:POWer:CARRier.......................................................................1008
[:SOURce<hw>]:AWGN:POWer:NOISe..........................................................................1009
[:SOURce<hw>]:AWGN:POWer:NOISe:TOTal?..............................................................1009
[:SOURce<hw>]:AWGN:POWer:SUM?.......................................................................... 1009
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?................................................................... 1010
[:SOURce<hw>]:AWGN:FREQuency:TARGet.................................................................1010
[:SOURce<hw>]:AWGN:FREQuency:RESult?.................................................................1010
[:SOURce<hw>]:AWGN:CMODe[:STATe] <State>
Couples the configuration of all streams.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Enabling/disabling the AWGN generator and the
streams" on page 1002
Manual operation: See "Coupled Mode" on page 396
[:SOURce<hw>]:AWGN:STATe <State>
Activates or deactivates the AWGN generator or the corresponding stream.
See also "Suffixes in the keywords ENTity<ch> and SOURce<hw>" on page 1002.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Enabling/disabling the AWGN generator and the
streams" on page 1002
Manual operation: See "State" on page 396
[:SOURce<hw>]:AWGN:MODE <Mode>
Determines how the interfering signal is generated.