Remote Control Commands
R&S
®
SMW200A
1007User Manual 1175.6632.02 ─ 16
Return values:
<Noise> float
Range: 0 to 200E6
Increment: 100
*RST: 0
Example: See Example "Generating an additive noise signal"
on page 1004
Usage: Query only
Manual operation: See "Noise Bandwidth" on page 403
[:SOURce<hw>]:AWGN:DISP:MODE
<Mode>
Sets the output to that the AWGN settings are related.
Parameters:
<Mode> RFA | RFB | IQOUT1 | IQOUT2 | BBMM1 | BBMM2 | FADER1 |
FADER2 | FADER3 | FADER4
*RST: RF
Example: See Example "Generating an additive noise signal"
on page 1004
Manual operation: See "Show Powers for Output" on page 399
[:SOURce<hw>]:AWGN:POWer:MODE <Mode>
Selects the mode for setting the noise level.
Parameters:
<Mode> CN | SN | EN
*RST: SN
Example: see Example "Generating an additive noise signal"
on page 1004
Manual operation: See "Set Noise Power Via" on page 399
[:SOURce<hw>]:AWGN:POWer:RMODe <RMode>
Determines whether the carrier or the noise level is kept constant when the C/N value
or Eb/N0 value is changed.
Parameters:
<RMode> CARRier | NOISe
*RST: CARRier
Example: See Example "Generating an additive noise signal"
on page 1004
Manual operation: See "Reference Mode" on page 399