Remote Control Commands
R&S
®
SMW200A
1017User Manual 1175.6632.02 ─ 16
Example:
BB:GRAP:SRAT:MODE USER
sets the sample rate mode.
Manual operation: See "Sample Rate" on page 571
[:SOURce]:BB:GRAPhics:CLOSe
Closes all graphical signal displays.
Usage: Event
Manual operation: See "Remove" on page 571
[:SOURce]:BB:GRAPhics:ADD
<Size>
Adds a graphical signal display (according to the current MODE, SOURce, SRATe:* and
TRIGger:* settings).
Setting parameters:
<Size> MAXimized | MINimized
Usage: Setting only
Manual operation: See "Add" on page 571
[:SOURce]:BB:GRAPhics:SOURce <Source>
Defines the signal acquisition point, that is the location in the signal flow where the dis-
played signal is tapped from.
The available acquisition points depend on the selected system configuration.
Parameters:
<Source> STRA | STRB | STRC | STRD | STRE | STRF | STRG | STRH |
BBA | BBB | BBC | BBD | BBE | BBF | BBG | BBH | RFA | RFB |
RFC | RFD | IQO1 | IQO2 | DO1 | DO2 | BBIA | BBIB
STRA|STRB|STRC|STRD|STRE|STRF|STRG|STRH
Streams (A ... H); input stream of the "IQ Stream Mapper"
BBA|BBB|BBC|BBD|BBE|BBF|BBG|BBH
Baseband signals (A ... H)
BBIA|BBIB
Digital baseband input signals
RFA|RFB|RFC|RFD
RF signals (A ... D)
IQO1|IQO2
Analog I/Q output signals
DO1|DO2
Digital I/Q output signals; outputs of the "IQ Stream Mapper"
*RST:
STRA
Manual operation: See "Source" on page 570
SOURce Subsystem