Remote Control Commands
R&S
®
SMW200A
1023User Manual 1175.6632.02 ─ 16
[:SOURce]:BB:MEASurement:POWer:PROGress?
Queries the status of the initiated measurement. The query returns a value that indi-
cates the task progress in percent.
Return values:
<Progress> float
Range: 0 to 100
*RST: 0
Example: See Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Usage: Query only
Manual operation: See "BB Powers Summary List" on page 595
[:SOURce]:BB:MEASurement:POWer:DURation
<Duration>
Sets the measurement's time of a single measurement.
Parameters:
<Duration> float
Range: 1E-3 to 5400
Increment: 1E-3
*RST: 1
Example: see Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Manual operation: See "Sweep Time/Duration" on page 596
[:SOURce]:BB:MEASurement:POWer:INDex <MeasIndex>
Selects the measurement index the subsequent settings apply to, for example chang-
ing, starting or removing form the list of measurements.
Parameters:
<MeasIndex> integer
Range: 1 to dynamic
*RST: 1
Example: see Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
Manual operation: See "Add, Change, Remove, Start, Abort" on page 597
[:SOURce]:BB:MEASurement:POWer:CHANge
Triggers the instrument to adopt the changed measurement configuration.
Example:
See Example "Querying information on burst baseband signals
using the multi-gated acquisition" on page 1019
SOURce Subsystem