EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 1045

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
1030User Manual 1175.6632.02 ─ 16
Example: See Example "Create a table with user-defined correction values
for the RF level" on page 1026 .
Manual operation: See "User Cor. Data" on page 532
[:SOURce<hw>]:CORRection:VALue?
Queries the current value for user correction.
Return values:
<Value> float
Range: -100 to 100
Increment: 0.01
*RST: 0
Example: See Example "Create a table with user-defined correction values
for the RF level" on page 1026 .
Usage: Query only
Manual operation: See "User Correction" on page 531
[:SOURce<hw>]:CORRection:ZERoing:STATe <State>
Activates the zeroing procedure before filling the user correction data acquired by a
sensor.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 1
Example: See Example "Fill user correction data with sensor"
on page 1027.
Manual operation: See " Fill User Correction Data with Sensor" on page 537
[:SOURce<hw>]:CORRection:CSET:DATA[:SENSor<ch>][:POWer]:SONCe
Fills the selected user correction list with the level values measured by the power sen-
sor for the given frequencies.
Suffix:
SENSor<ch>
.
Defines the used power sensor, i.e. the sensor whose values
are used.
Example: See Example "Fill user correction data with sensor"
on page 1027.
Usage: Event
[:SOURce<hw>]:CORRection[:STATe] <State>
Activates user correction with the currently selected table.
SOURce Subsystem

Table of Contents

Related product manuals