Remote Control Commands
R&S
®
SMW200A
1051User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:IQ:WBSTate <WbState>
Activates wideband mode.
This setting automatically optimizes the settings for wideband modulation signals
(>5 MHz, State ON).
Parameters:
<WbState> 0 | 1 | OFF | ON
*RST: 0
Example:
IQ:WBST ON
switches to wideband mode.
Manual operation: See "I/Q Wideband" on page 420
13.18.9 SOURce:IQ:OUTPut Subsystem
The SOURce:IQ:OUTPut subsystem contains the commands for configuring the ana-
log and digital I/Q output signals.
For information about the required options, see:
●
Chapter 3.7, "I/Q Digital Output Settings", on page 178
●
Chapter 3.8, "I/Q Analog Output Settings", on page 185
Refer to Table 3-4 for information on the connector and interfaces the analog and digi-
tal I/Q signals are output at.
13.18.9.1 SOURce:IQ:OUTPut:ANALog Commands
This section describes the commands of the output of an analog I/Q signal.
Example: Enabling and configuring the analog output
SCONfiguration:OUTPut:MAPPing:IQOutput1:STReam1:STATe 1
SOURce1:IQ:OUTPut:ANALog:PRESet
SOURce1:IQ:OUTPut:ANALog:TYPE DIFF
SOURce1:IQ:OUTPut:ANALog:MODE VAR
SOURce1:IQ:OUTPut:LEVel 2
SOURce1:IQ:OUTPut:ANALog:BIAS:COUPling:STATe 1
SOURce1:IQ:OUTPut:ANALog:BIAS:I 1
SOURce1:IQ:OUTPut:ANALog:BIAS:Q?
// 1
SOURce1:IQ:OUTPut:ANALog:OFFSet:I 2
SOURce1:IQ:OUTPut:ANALog:OFFSet:Q 2.5
SOURce1:IQ:OUTPut:ANALog:STATe 1
[:SOURce<hw>]:IQ:OUTPut:ANALog:STATe..................................................................1052
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:PRESet...............................................................1052
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:CATalog?.............................................. 1052
SOURce Subsystem