Remote Control Commands
R&S
®
SMW200A
1059User Manual 1175.6632.02 ─ 16
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:POWer:LEVel <Level>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer:LEVel <Level>
Enters the RMS level of the output signal.
Parameters:
<Level> float
Range: -60 to 0
Increment: 0.01
*RST: 0
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:POWer:LEVel -10
Manual operation: See "Signal Output" on page 183
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:POWer:STEP:MODE <Mode>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer:STEP:MODE <Mode>
Defines the type of step size to vary the digital output power step-by-step.
Parameters:
<Mode> DECimal | USER
DECimal
increases or decreases the level in steps of ten.
USER
increases or decreases the level in increments, determined with
the command [:SOURce]:IQ:OUTPut:DIGital:
FADer<ch>:POWer:STEP[:INCRement].
*RST: DECimal
Example:
:SOURce:IQ:OUTPut:DIGital:BBMM2:POWer:STEP:MODE
USER
:SOURce:IQ:OUTPut:DIGital:BBMM2:POWer:STEP 5 dB
Activates the step width for level variation in 5 dB steps
Manual operation: See "User Variation" on page 183
[:SOURce]:IQ:OUTPut:DIGital:BBMM<ch>:POWer:STEP[:INCRement]
<Increment>
[:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer:STEP[:INCRement]
<Increment>
Sets the step width. Use this value to vary the digital I/Q output level step-by-step.
Parameters:
<Increment> float
Range: 0 to 100
Increment: 0.01
*RST: 1
Example: See [:SOURce]:IQ:OUTPut:DIGital:FADer<ch>:POWer: