Remote Control Commands
R&S
®
SMW200A
1090User Manual 1175.6632.02 ─ 16
Example: Using pulse generator as source for pulse modulation
// select pulse generator as source for pulse modulation
// enable pulse modulation
SOURce1:PULM:SOURce INT
SOURce1:PULM:STATe 1
// pulse generator and signal output are also activated
SOURce1:PGENerator:STATe?
// 1
SOURce1:PGENerator:OUTPut:STATe?
// 1
PGENerator:OUTPut:POLarity NORMal
// to disable pulse generator
SOURce1:PGENerator:STATe 0
// activate the pulse modulation of the RF carrier
SOURce1:PULM:STATe 1
[:SOURce<hw>]:PGENerator:OUTPut:POLarity.............................................................. 1090
[:SOURce<hw>]:PGENerator:OUTPut[:STATe]...............................................................1090
[:SOURce<hw>]:PGENerator:STATe............................................................................. 1091
[:SOURce<hw>]:PGENerator:OUTPut:POLarity <Polarity>
Sets the polarity of the pulse output signal.
Parameters:
<Polarity> NORMal | INVerted
NORMal
Outputs the pulse signal during the pulse width, that means dur-
ing the high state.
INVerted
Inverts the pulse output signal polarity. The pulse output signal
is suppressed during the pulse width, but provided during the
low state.
*RST: NORMal
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 1090.
Manual operation: See "Pulse Output Polarity" on page 516
[:SOURce<hw>]:PGENerator:OUTPut[:STATe] <State>
Activates the output of the pulse modulation signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Using pulse generator as source for pulse modu-
lation" on page 1090.