Getting Started
R&S
®
SMW200A
99User Manual 1175.6632.02 ─ 16
Figure 2-16: Block diagram of a fully equipped two path instrument (4x4 MIMO configura-
tion)
For more examples, see also
Chapter 2.4.2, "Applications Examples of the
R&S SMW", on page 102.
The cross-reference between the installed options and the displayed settings
The Table 2-11 is an excerpt of the available options and lists only the options required
to display a functional block in the block diagram. The information assumes R&S SMW
equipped with standard baseband generator R&S SMW-B10 and R&S SMW-B13T.
For exact information on the available options, and on the minimum requirements and
the interdependencies between the provided options, refer to the R&S SMW data
sheet.
Table 2-11: Required options per functional block (excerpt)
Functional block Required option
"Baseband A" R&S SMW-B10
"Baseband B" Second option R&S SMW-B10
"BB Input A" Included in R&S SMW-B10
"BB Input B" Included in second option R&S SMW-B10
"Fading A" R&S SMW-B14
"Fading B" Second option R&S SMW-B14
"AWGN A"/"AWGN B" At least one option R&S SMW-K62
"I/Q Stream Mapper" -
"I/Q Mod A" R&S SMW-B103/-B106
"I/Q Mod B" R&S SMW-B203/-B206
"I/Q Analog A" R&S SMW-B13
System Overview