Elements and Controls of the Graphical User Interface
R&S
®
SMW200A
1238User Manual 1175.6632.02 ─ 16
Example: Naming conventions in standard mode
The name of the "AWGN" functional block and the name of the "AWGN Settings" dia-
log (see Figure D-1) is formed as follows:
"<AWGN> + <Stream A >= <AWGN A>"
Figure D-1: Explanation of the naming convention for standard mode
1 = dialog refers to "Baseband B"
2a, 2b = dialog and functional blocks refer to "Stream A"/"Stream B"
●
Advanced mode
In Advanced mode, the functional blocks are not always dedicated to a stream/
baseband. The applied naming rule depends on further settings, like the selected
baseband source and number of entities.
– While using Coupled sources, there is only one functional block that provides
specific configuration settings for all streams/basebands. Hence, there is no
special attachment to the name of the functional block/dialogs:
"<Functional block> = <Functional block/Dialog>"
– In multiple entity mode, one functional block controls the settings of several
streams. To indicate this, the number of the entity is appended to the name of
the dialog:
"<Functional block> + <Entity number> = <Functional block/Dialog>"
Naming Conventions in the User Interface