Configuring the Internal Baseband Source
R&S
®
SMW200A
336User Manual 1175.6632.02 ─ 16
Segment Marker..........................................................................................................336
Sequence Restart....................................................................................................... 337
Segment Restart......................................................................................................... 337
Level
Defines the way the instrument determines the output level of each of the multiple
waveforms.
"Unchanged"
Concerning the level settings, the segments are output exactly as
defined in the individual files. The "Level" display applies only to the
segment with the highest RMS value. Sometimes, the remaining seg-
ments are output at a lower level than the displayed value.
"Equal RMS"
Segments are output so that all segments have the same RMS value.
The "Level" display applies to all segments.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE]
on page 941
Clock
Defines the way the instrument determines the clock rate of each of the multiple wave-
forms.
"Unchanged"
Each segment is output with the clock rate defined in its waveform
file.
Note: Segments with equal clock rates are required for "Next Seg-
ment Mode > Next Segment Seamless".
"Highest"
All segments are output at the highest available clock rate.
Note: Trade-off between fast switch over and computing time. This
mode provides short switch over times between segments.
However, the computing time increases because the individual seg-
ments are resampled.
"User"
All segments are output at the clock rate defined by the parameter
"User Clock".
This mode is a trade-off between fast switch over and computing
time, too.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE
on page 941
User Clock Rate
Defines the sample rate used for multi-segment waveform output, if "Clock Mode >
User" is selected.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk on page 940
Segment Marker
Defines the way the marker information within the separate segments is processed,
see also Chapter 4.8.2.4, "Impact of the Marker Settings", on page 326.
Generating Multi-Segment Waveform Files

Table of Contents