Configuring the Internal Baseband Source
R&S
®
SMW200A
374User Manual 1175.6632.02 ─ 16
The remote commands required to define these settings are described in Chap-
ter 13.18.4.5, "SOURce:BB:MCCW Subsystem", on page 983.
Settings:
4.10.3.1 General Carrier Settings
Access:
► Select "Baseband > Multi-Carrier CW".
Settings:
State............................................................................................................................374
Set to Default.............................................................................................................. 375
Number of Carriers......................................................................................................375
Carrier Spacing........................................................................................................... 375
Clock Frequency......................................................................................................... 375
Optimize Crest Factor Mode....................................................................................... 375
Desired Crest Factor...................................................................................................376
State
Enables/disables the Multi-Carrier CW.
Switching on this option, turns off all the other digital standards and digital modulation
modes in the corresponding signal path.
Multi-carrier CW signals are computed in arbitrary waveform mode. To adopt the
changes in the settings of individual carriers, select "Accept". This applies to the set-
tings in the "Table Setup Assistant" section and the "Carrier Table" dialog.
Generating Multi-Carrier Continuous Wave Signal