Configuring the Signal in the RF Domain
R&S
®
SMW200A
476User Manual 1175.6632.02 ─ 16
└ Repeat.......................................................................................................... 477
└ Start Trigger..................................................................................................477
└ Point Trigger................................................................................................. 477
Execute Single Sweep ............................................................................................... 477
Reset Sweep ..............................................................................................................478
Start Frequency/Stop Frequency ............................................................................... 478
Start Level / Stop Level ..............................................................................................478
Center Frequency ...................................................................................................... 478
Span............................................................................................................................478
Current Frequency...................................................................................................... 478
Current Level...............................................................................................................479
Spacing....................................................................................................................... 479
Shape .........................................................................................................................479
Retrace........................................................................................................................479
Step Linear/Step Logarithmic .....................................................................................480
Step ............................................................................................................................480
Dwell Time ................................................................................................................. 480
Trigger Slope...............................................................................................................480
State (RF frequency sweep)
Activates RF frequency sweep signal generation.
Note: Active sweep mode deactivates other sweeps or lists and vice versa.
Remote command:
[:SOURce<hw>]:FREQuency:MODE on page 1041
State (RF level sweep)
Activates RF level sweep signal generation.
Note: Active sweep mode deactivates other sweeps or lists and vice versa.
Remote command:
[:SOURce<hw>]:POWer:MODE on page 1098
State (LF frequency sweep)
Activates the generation of an LF frequency sweep signal in the "LF Frequency" dialog.
In the "Sources" tab of the analog modulations, the instrument shows the current state
of the LF frequency sweep.
Note: Active sweep mode deactivates other sweeps or lists and vice versa.
Remote command:
[:SOURce<hw>]:LFOutput:FREQuency:MODE on page 1065
Mode
Selects the sweep mode.
For detailed information on the sweep modes and the triggering, see Chapter 7.6.1,
"Signal Generation and Triggering in the Sweep and List Modes", on page 459.
"Auto"
Generates a continuously repeating sweep signal directly after acti-
vating the sweep mode.
The sweep steps are performed automatically, controlled by the dwell
time.
Varying the RF Signal in List or Sweep Mode