Remote Control Commands
R&S
®
SMW200A
841User Manual 1175.6632.02 ─ 16
Parameters:
<Mode> SINGle | ADD | MULTiplex
ADD enabled for the RF, I/Q OUT and BBMM outputs
MULTiplex enabled for the BBMM outputs and
:SCONfiguration:OUTPut:MODEDIGMux
*RST: SINGle
Example: see Example "Distributing the I/Q streams to the output connec-
tors (advanced configuration)" on page 826
see Example "Generating digital multiplexed signals"
on page 832
Options: MULTiplex requires R&S SMW-K551
Manual operation: See "Combination Mode" on page 146
:SCONfiguration:OUTPut:MAPPing:STReam<st>:FOFFset <SmFreqOffset>
Sets an absolute frequency offset and shifts streams routed to the RF, I/Q OUT and
BBMM connectors in the frequency domain.
Parameters:
<SmFreqOffset> float
Range: depends on the installed options, e.g. -60E6 to
+60E6 (R&S SMW-B10)
Increment: 0.01
*RST: 0
Example: See Example "Distributing the I/Q streams to the output connec-
tors (advanced configuration)" on page 826
Manual operation: See "f
offset
, MHz" on page 145
:SCONfiguration:OUTPut:MAPPing:STReam<st>:POFFset <SmPhasOffset>
Sets the phase offset of the corresponding stream.
Parameters:
<SmPhasOffset> float
Range: -999.99 to 999.99
Increment: 0.01
*RST: 0
Example: see Example "Distributing the I/Q streams to the output connec-
tors (advanced configuration)" on page 826
Manual operation: See "Phase, deg" on page 146
13.17.4 External RF and I/Q Instruments
Option: R&S SMW-B10 for commands with the keywords BBMM<ch> and FADer<ch>.
SCONfiguration Subsystem

Table of Contents