Remote Control Commands
R&S
®
SMW200A
896User Manual 1175.6632.02 ─ 16
Manual operation: See "Bit Order" on page 272
[:SOURce<hw>]:BB:DM:SMODulation:CDTDeviation <Deviation>
Queries the timing deviations (time offset) between the clock and the data signals.
Parameters:
<Deviation> float
Range: -5E-3 to 5E-3
Increment: 1E-12
*RST: 0
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 895.
Options: R&S SMW-B10
Manual operation: See "Clock to Data Time Deviation" on page 272
[:SOURce<hw>]:BB:DM:SMODulation:CLOCk:SLOPe:BIT <Slope>
Sets the active edge of the bit clock.
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 895
Options: R&S SMW-B10
Manual operation: See "Bit Clock Slope" on page 272
[:SOURce<hw>]:BB:DM:SMODulation:THRoughput:DELay?
Queries the throughput delay from the data input to the RF output in the case of exter-
nal modulation.
Return values:
<Delay> integer
Range: -100 to 100
Increment: 250E-12
*RST: 0
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 895
Usage: Query only
Options: R&S SMW-B10
Manual operation: See "Throughput Delay" on page 272