Chapter 5 Operation
5300.9677.71 - 5.41 - EN-4
Display Explanation
RF Displays the status of the RF output:
– Off
There is no RF level at the exciter output since the RF output is not
enabled ("manually" disabled)
– Ok
The RF level at the exciter output is OK
– Fault
There is no RF level at the exciter output even though the RF output
is enabled
Mainboard Sum status of the mainboard (detailed information in the "Mainboard"
submenu):
– OK
Mainboard is functioning normally
– Warning
At least one monitored parameter is outside the tolerance; the device
is, however, still functioning in compliance with the specifications
– Error
At least one monitored parameter is outside the tolerance; the device
is no longer functioning correctly
Audio Ch1 Status of channel 1 (primary audio input):
(the input type is set in the "Input > Automatic Input" menu window)
– OK
Channel 1 is functioning normally.
– One Ch. Not OK
In the case of Stereo or Mono L+R modulation, this status is displayed
if just one of the two feeds for left and right is functioning normally
while the other feed is faulty.
– Not OK
Channel 1 has failed completely.