065 75$16&(,9(5 ; $ ; $
Operator’s Manual Malfunction
– 4.10 – 6076.0822.12.01
 (UURU/LVW
Check the error code and proceed as indicated in the Action column (in most cases the radio
will need to be transferred to the nearest depot facility).
1RWH
(UURUFRGHV[[[DUHQRWOLVWHGLQWKHWDEOH,I,%,7VHHFKDSWHUUHWXUQVD[[[HUURU
FRGH,%,7PXVWEHUHSHDWHG,IWKHHUURUSHUVLVWVVHQGWKHUDGLRWRWKHGHSRW
Code Message Level Notes Action
(CBIT message,
frequent or single event)
0001 GR CNAPI ERR W Inform depot.
0002 GR General Software Error W Inform depot.
0003 GR ERR STR FULL W Error store full Inform depot.
0004 GR FLASH CHCKS ERR E Checksum error of Flash
EEPROM
Inform depot.
0100 PL +2.5 V LOW E Platform error:
+25-V reference voltage
low
Send radio to depot.
0101 PL V_BATT LOW W Platform warning:
33-V battery low
Send radio to depot
(replace the platform battery).
0102 PL V_RET LOW E Platform error:
Retention voltage low
Send radio to depot.
0103 PL INT +10V LOW E Platform error:
Internal voltage +10 V low
Send radio to depot.
0105 PL INT -10V LOW E Platform error:
Internal voltage -10 V low
Send radio to depot.
0106 PL OVERTEMP W Platform warning:
Overtemperature
Check airflow of fans and ambient
temperature. If this fails to eliminate
the fault, send radio to depot.
0150 PL SRAM BATT EMPTY W Platform warning:
SRAM battery is low
Send radio to depot
(replace the platform SRAM battery).
0200 PS -12V LOW E DC power supply error:
Voltage -12 V low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0201 PS +3.3V LOW E DC power supply error:
Voltage +33 V low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0202 PS +5V LOW E DC power supply error:
Voltage +5 V low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0203 PS +12V LOW E DC power supply error:
Voltage +12 V low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action
0204 PS +33V LOW E DC power supply error:
Voltage +33 V low
CBIT message or frequent event:
Send radio to depot.
Single event:
no action

Related product manuals