Command Reference
R&S
®
ZNB/ZNBT
1003User Manual 1173.9163.02 ─ 54
Example:
CONTrol:GPIO:SENSe:SUMCurrent? 1,2,3,4,5
returns the sum of the currents measured in GPIO ports 1 to 5
Usage: Query only
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Voltage, Current" on page 523
CONTrol<Ch>:GPIO:SENSe:TRIGger
Starts the voltage/current measurements on all GPIO pins.
The measurement time can be defined using CONTrol<Ch>:GPIO:TIME.
Suffix:
<Ch>
.
Channel number
This suffix is ignored and can be omitted.
Usage: Event
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Meas" on page 523
CONTrol<Ch>:GPIO:TIME <MeasTime>
Sets the measurement time for the voltage/current measurements on the RFFE and
GPIO pins.
Same functionality as CONTrol<Ch>:RFFE:TEST:TIME.
Suffix:
<Ch>
.
Channel number
This suffix is ignored and can be omitted: the measurement time
is valid for all channels.
Parameters:
<MeasTime> Measurement (= sampling = averaging) time
Range: 95 μs to 100 ms
*RST: 100 ms
Default unit: s
Options: R&S ZN-B15/Z15 Var. 03
Manual operation: See "Meas" on page 523
CONTrol<Ch>:GPIO:VOLTage:OUTPut
Applies the current output voltage and current range (shunt) settings to the RFFE/
GPIO pins.
Same function as CONTrol<Ch>:RFFE:TEST:OUTPut on page 1013.
Suffix:
<Ch>
.
Channel number