GUI Reference
R&S
®
ZNB/ZNBT
513User Manual 1173.9163.02 ─ 54
The order of all channels in a recall set is given by the channels' creation time. By
default, the channels are named Ch1, Ch2, ... so that Ch<n – 1> precedes Ch<n>. This
order is always maintained, even if channels are renamed, invisible (because no traces
are assigned to them) or distributed over several diagram areas.
Tip: You can also select a line in the channel list to activate the corresponding channel.
Remote command:
The numeric suffix <Ch> appended to the first-level mnemonic of a command selects a
channel as the active channel.
New Channel
Creates a channel and a trace with default settings, and assigns the new trace to the
active diagram area.
The new channel is named Ch<n>, where <n> is the largest of all existing channel
numbers plus one. The name can be changed in the "Channel Manager" dialog.
Tips:
To create a channel and a trace with default settings and to display the trace in a
new diagram area, use New Channel + Diagram.
Use Add Trace to create a trace in the active channel.
Remote command:
CONFigure:CHANnel<Ch>[:STATe] ON
CALCulate<Ch>:PARameter:SDEFine
DISPlay[:WINDow<Wnd>]:TRACe<WndTr>:FEED
CONFigure:TRACe<Trc>:CHANnel:NAME?
CONFigure:TRACe<Trc>:CHANnel:NAME:ID?
Copy Channel
Copies the active channel with all its settings (including a possible channel calibration)
and traces. The new traces are displayed in the active diagram area.
The new channel is named Ch<n>, where <n> is the largest of all existing channel
numbers plus one. The name can be changed in the "Channel Manager" dialog.
Tips: Use Copy Channel + Diagram to display the copied traces in a new diagram
area.
Remote command:
CONFigure:CHANnel<Ch>[:STATe] ON
CALCulate<Ch>:PARameter:SDEFine
DISPlay[:WINDow<Wnd>]:TRACe<WndTr>:FEED
CONFigure:TRACe<Trc>:CHANnel:NAME?
CONFigure:TRACe<Trc>:CHANnel:NAME:ID?
New Channel + Diagram
Creates a channel and a trace with default settings, and assigns the created trace to a
new diagram area.
The new channel is named Ch<n>, where <n> is the largest of all existing channel
numbers plus one. The name can be changed in the "Channel Manager" dialog.
Tip: To create a channel and a trace with default settings and to display the trace in the
active diagram area, use New Channel.