R&S ZVL Command Reference
Instrument-Control Commands
Operating Manual 1303.6580.32-05
459
path is omitted, the current directory is used (see MMEMory:CDIRectory).
*RST value
SCPI, Command
Types
Confirmed, no query.
Example:
MMEM:DEL 'C:\TEMP\TEST01.HCP'
Remove TEST01.HCP from the directory C:\TEMP.
MMEMory:DELete:CORRection <file_name>'
Deletes a system error correction data set stored in the cal pool (cal group file).
'<file_name>'
String parameter to specify the name of the cal group file to be deleted. Cal group
files must have the extension *.cal. The directory path must not be specified; the
analyzer always uses the default cal pool directory
C:\R_S\Instr\user\Nwa\Calibration\Data.
*RST value
SCPI,
Command
Types
Device-specific, no query.
Example:
See MMEMory:LOAD:CORRection
MMEMory:LOAD:AUTO 1,'FACTORY | <file_name>'
Defines which device settings are automatically loaded after the device is switched on. The contents of the
file are read after switching on the device and used to define the new device state.
The data set defined as auto recall set can also be restored by the *RST command.
FACTORY
Deactivates the startup recall function.
<file_name>
Activates the startup recall function and defines the device settings to be
loaded.
*RST value
SCPI, Command
Types
Device-specific, no query.
Example:
MMEM:LOAD:AUTO 1,'C:\R_S\Instr\user\TEST'
Define the TEST file as startup recall file and activate the function.
MMEMory:LOAD:CABLe '<source_directory>'
Loads all cable description files (*.rsc) from a specified directory. The default source directories for cable