3 Replacement of Main Parts
48
3
14
Connect the INSULOCK TIEs and the Sponge as the figure.
Tighten up the Spindle Motor Cable Bush.
Connect the Z Motor Cable, Z Limit Cable and Spinle Motor
Cable to the XY Junction Board.
Then, fix the Limit Switch and the Junction Board Cover.
13
Be careful with the position of the Sponge.
It is necessary to put it beside the Cable Holder.
Sponge and
INSULOCK TIE
INSULOCK
TIEs
Cable
Holder
15
Turn on the Power while pressing the [ ], [ ], [ ]
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
<Z Axis Load Check>
Spindle Cable Bush
12
Tighten up the screws fixing the Carriage Unit.
Screws
Carriage Unit
CHECK MODE
LOAD CON. CARD
[ ], [ ], [ ] + POWER ON
[ENTER] key
[MENU] key