3 Replacement of Main Parts
55
3
Standard Plane
Remove the screws fixing the LM Block on the Carriage Rail
and loosen the Set Screws.
4
5
Set
Screws
Hold the Carriage Rail up and take the LM Guide off. Then,
fix the new LM Guide by tightening screws temporarily.
Carriage Rail
When fixing the Y LM Guide, be careful with the
direction.
Fix the Y LM Guide fitting the standard plane with
direction as the figure.
Y LM Guide
Carriage
Rail
Y LM
Guide
Carriage Rail
3
Remove the screws fixing the LM Guide.
LM Guide
LM Block