4 - TOUCH SCREEN TEST
Note: To carry out this test, it is better to use the original pen (Touch Pen for PMA-5,
code 00900545).
Press the USER PROGRAM 4 button the display shows:
Pressing USER PROGRAM 1 button, you can enter in the CALIBRATION test;
Pressing USER PROGRAM 2 button, you can enter in the “blue” section test.
4.1 - TOUCH SCREEN CALIBRATION
Press the USER PROGRAM 1 button the display shows:
Press this point
-- TOUCH SCREEN CALIBRATION --
1
2
3
4
Calibrate the Touch Screen position as mentioned below.
Use the original pen (Touch Pen for PMA-5, code 00900545).
Touch with the pen the Touch Screen corners in the middle of the “+” symbol following the
numbering shown in the picture. When the G-70 recognizes the touch, the symbol “+”
changes into “0”.
The writing “PRESS THIS POINT” should appear to show the correct order. During the
calibration, we recommend not to touch any other point expect for the ones shown with the
writing “PRESS THIS POINT”.
After touching the four points, the calibration is over and the display will show one of the
following videos:
In case of a positive outcome of the calibration.
**** TOUCHSCREEN ****
1 : CALIBRATION
2 : TOUCH X, Y
Press EXIT to Ski
p
Calibration OK