EasyManua.ls Logo

Roland HP-335 - Test Mode - Entry and Device Check; Entering and Navigating Test Mode; Device Check and ROM Version Display

Roland HP-335
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Nov. 1998
12
HP-335
KEYBOARD PA-4A88-C2 CIRCUIT DIAGRAM
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
TEST MODE
Required items
MIDI cable (1.5m or longer Part No.23485229 1.5m)
Computer test cable for SOUND CANVAS SC-88 (Part No.17049906)
Microphone
Oscilloscope
1. To enter the test mode
Get into the FUNCTION MODE from pressing [Function] button after
turning the power On. (Each LED may brink.)
Then press [Function] button while holding down the [Track 2] and
[Play] buttons. 'JIG' is displayed and the piano shall automatically enter
into the TEST MODE.
Press [Function] button to get into stage 2.
* To exit the Test Mode, turn the power Off.
* To proceed on the next mode, press [Function] button. However,
there are some mode that will move to the next item automatically.
Please refer to the explanations written to the each mode.
NOTE : When there is a malfunction during the TEST MODE,
switch the power On again.
2. Display of DEVICE CHECK, ROM VERSION
* DEVICE CHECK
When enter into the TEST MODE, the DEVICE CHECK will be
executed automatically. If there is no malfunction, ROM VERSION is
displayed to the 7-SEG LED.
In the event of a malfunction, one of the following shall be displayed.
7-SEG LED Failed DEVICE
: Program ROM
: Working DRAM
: Wave ROM
: DSP RAM
Press [Function] to go on the TEST MODE.
* BUILD NUMBER
This numbers are displayed for factory purpose only, please
ignore when you execute test mode.