EasyManua.ls Logo

Roland M-400 - SCC: Scene Recall; RSC: Relative Scene Recall

Roland M-400
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Command details
SCC: Scene recall
Function Recalls a scene memory.
Syntax stxSCC:a; (Command syntax: type 2)
a: Scene number (000–299)
<Ex.> stxSCC:010;
Recalls scene number 010.
Note: If you specify a blank scene, the M-400 will return an ERR command (stxERR:5;) and ignore your command.
RSC: Relative scene recall
Function Recalls a scene memory relatively; e.g., “the previous memory” or “two scenes ahead.”
Syntax stxRSC:a; (Command syntax: type 2)
a: Relative scene number (-299–299)
<Ex.> stxRSC:-3;
Recalls the scene memory three memories earlier than the current scene number.
Note: If the scene memory number specified by relative scene is one of the following scenes, the M-400 will return an ERR
command (stxERR:5;) and ignore your command.
• A blank scene.
• A scene number outside the range of 0–299.

Other manuals for Roland M-400