EasyManua.ls Logo

Roland M-400 - Request Commands; CNQ: Channel Name Request; PTQ: Phantom Power Supply Request

Roland M-400
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Command details
CNQ: Channel name request
Function Requests the channel/group name.
Syntax stxCNQ:a; (Command syntax: type 2)
a: Channel selection (I1–I48, AX1–AX16, MAL, MAR, DCA1–DCA8 or U1–U24)
<Ex.> stxCNQ:I1;
Requests the channel name of CH1.
Command returned by the M-400
Syntax stxCNS:a,“b”; (Command syntax: type 2)
a: Channel number (I1–I48, AX1–AX16, MAL, MAR, DCA1–DCA8 or U1–U24)
b: Channel name (fixed at six characters)
<Ex.> stxCNS:I1,”A.BASS”;
Output the channel name A.BASS for CH1.
Note: If the channel name is blank, the output will be six spaces.
PTQ: Phantom power supply request
Function Requests the on/off status of the +48V phantom power supply.
Syntax stxPTQ:a; (Command syntax: type 2)
a: Channel selection (I1–I48, U1–U24)
<Ex.> stxPTQ:I1;
Requests the on/off status of the +48V phantom power supply for CH1.
Command returned by the M-400
Syntax stxPTS:a,b; (Command syntax: type 2)
a: Channel number (I1–I48, U1–U24)
b: On/off
0 (Off)
1 (On)
<Ex.> stxPTS:I1,0;
Reports that the CH1 phantom power is off.
Note: If you specify the following parameters, the M-400 will return an ERR command (stxERR:5;) and will ignore your
command.
• If you specify a channel that does not have phantom power
• If you specify U1–U24 that is assigned to the above
Request commands

Other manuals for Roland M-400

Related product manuals