EasyManua.ls Logo

Roland M-480 - Remote; Remote Functions Overview (MIDI, V-LINK, USB MIDI, RS-232 C)

Roland M-480
229 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
106
Effects and GEQ
Effects and GEQ
Editing the GEQ parameters
The GEQ EDIT popup is used to edit the GEQ.
1.
Access the EFFECTS screen, and display the GEQ 1–6
(GEQ 7–12) tab.
2.
Move the cursor to the EDIT button for the desired GEQ,
and press [ENTER].
fig.ScrGEQEdit.eps
The GEQ EDIT popup will appear.
You can also make the setting for accessing the popup from a
USER button (p. 140).
31-band GEQ
fig.ScrGEQEdit_Guide.eps
Analyzer display
This shows a 31-band realtime analyzer and the source level.
SRC (source)
This selects the source for the analyzer.
WINDOW
Here you can move the analyzer’s vertical display region in a
range of 0 dB – -48 dB.
AVG (average)
Here you can select the averaging method for the analyzer:
AVG TIMES (average times)
This specifies the value (1–128) by which the analyzer’s
display will be averaged.
PEAK HOLD button
When this is on, the analyzer’s peaks will be held.
The Hold time is specified by the HOLD TIME setting of the
METER SETUP popup.
IN meter
This indicates the level of the signal input to the GEQ
OUT meter
This indicates the level of the signal output from the GEQ
LINK button
This links adjacent odd-numbered and even-numbered GEQ
processors. If processors are linked, their GEQ settings will be
Accessing the GEQ EDIT popup
OFF
Averaging will not be performed.
NRM Averages evenly by the number specified in the
AVG TIMES.
EXP Recent times will be weighted more heavily in the
calculation.
1
7
8
9
10
2
12
11
13 14 15
3 4 5 6
1
2
3
4
5
6
7
8
9
M-480_e.book 106 ページ 2011年3月2日 水曜日 午前9時20分